Place of Origin: | China |
Brand Name: | HYE |
Certification: | CE,UL, ISO9001 |
Model Number: | SWM150M156 |
Minimum Order Quantity: | 1 |
---|---|
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 3000pcs/month |
Peak Power Watts Pmax: | 150W | Power Output Tolerance Pmax: | +3% |
---|---|---|---|
Maximum Power Voltage Vmp(V): | 18.2V | Maximum Power Current Impp: | 8.24A |
150W IP65 36Cells Solar Panel Home Solar And Wind Power Systems For Home
ADVANTAGE:
1.Guaranteed power output 0-3%
2.Sleek Appearance ,Advailable with black frame
3.Stringent Quality Control ,All modules undergo electrical,performance test ,1000V insulation test,and electroluminescence test
4.Reliable Performance ,Anti-reflective glass coating and advanced cell surface texturing to better capture direct and indirect light"Lower Temperature coefficient for higher output in hot conditions"
Specification Data
Peak Power Watts Pmax | 150W |
Power Output Tolerance Pmax | +3% |
Maximum Power Voltage Vmp(V) | 18.2V |
Maximum Power Current Impp |
8.24A |
Open Circult Voltage Voc |
22.5V
|
Short Circult Current | 8.76A |
Cell Efficiency nm | 18% |
Solar Cells | Mono-crystalline 156*156mm(6 in) |
Cell Orientation |
36 cells (4*9) |
Module Dimension | 1482*676*35mm (58.3*26.6*1.38in) |
Weight | 12kg(24lb) |
Glass | High transparency solar glass 3.2mm(0.13in) |
Frame | Anodized aluminium alloy |
J-Box |
IP 65 rate |
Connector |
Original MC4 PLUS |
Nominal Operating Cell Temperature | 45ºC(+-2ºC) |
Temperature Coefficient of Pmax | -0.43%/c |
Temperature Coefficient of Voc | -0.32%/c |
Temperature Coefficient of Isc | 0.047%/c |
Operational Temperature | -40ºC~+85ºC |
Maximum System Voltage | 1000V DC (IEC)/600V DC(UL) |
Max Series Fuse Rating | 15A |
Remarks:
1. System inverter is designed with total capacity 3000W, which means total load capacity of the house should be no more than 3000W, inverter will automatically shut down if instant load over 3000W for system self-protection, so we suggest end user to estimate your own house total load capacity then select the proper inverter system.
2.Air conditioner is not recommended for this system because air conditioner is a high power consumption unit which consumes 5-8KWH,if the house has to be equiped with air conditioner, we suggest supply the power for air conditioner from public grid.
3.There is an optional by-pass switch which could automatically switch to public grid power when there is not enough power in battery bank, this is only applicable to the area with public grid connection.